2n M2M Solution 2N SmartCom - User Manual 1.9.0 Manual de usuario Pagina 38

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 149
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 37
382N TELEKOMUNIKACE a.s., www.2n.cz
®
Enter the command to change the status of relay 2. The relay will be in the
position as before restart after the terminal restart.
at^screl2=1
Enter the command to change the status of relay 2.
at^screl2=1,0
Enter the command to change the status of relay 2. The relay will be in the
opposite position after restart.
at^screl2=1,1
Enter the command to change the status of relay 2. The relay will be in this
position after restart.
at^screl2=1,2
Enter the command to change the status of relay 2. The relay will be in the
position as before restart after the terminal restart.
ADC – Input Circuits
These commands help control the input circuits, set calibration and make
measurements.
at^scadc1="get_value"
Enter the command to measure the value of the selected port and send the
measured value.
at^scadc1="adc_value"
Enter the command to make the measurement and return the A/D converter
value.
at^scadc1="calib_min"
Enter the command to make automatic port calibration according to the currently
measured value.
at^scadc1="calib_max"
Enter the command to make automatic port calibration according to the currently
measured value.
at^scadc1="threshold_low",200
Manual calibration setting (minimum values). Setting options: 0 – 960.
at^scadc1="threshold_high",250
Vista de pagina 37
1 2 ... 33 34 35 36 37 38 39 40 41 42 43 ... 148 149

Comentarios a estos manuales

Sin comentarios