2n SmartGate - User Manual Manual de usuario

Busca en linea o descarga Manual de usuario para Accesorios de comunicación 2n SmartGate - User Manual. 2N SmartGate - User Manual User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 2 - Dear customer

52.6. Power Supply Connection SmartGate is powered with 10-16V DC. Where a source other than the included power supply adapter is used, the voltage

Pagina 3 - Upgrade

63. SmartGate Status Indication 3.1. Indication LEDs Name Meaning Power supply · Light = SmartGate is powered. · Flashes once in 2s = HW error

Pagina 4 - Packing List

73.2. Telephone Line Tones 3.2.1. Status Tones The GSM gateway sends tones to the telephone line to indicate the line status. The tone frequency is

Pagina 5 - CONTENTS

84. SIM Card PIN protection If a SIM card is PIN-protected and the PIN is not programmed in SmartGate, GSM LED indicates the state and the PIN tone

Pagina 6 - 1. SmartGate purpose

94.3. Automatic PIN Entering You need not enter the PIN upon power up if it is stored in SmartGate – it is entered automatically. This function is u

Pagina 7 - 2. Installation

105. Voice function Outgoing and incoming call establishing procedures is for illustration described for analog phone connected to FXS interface and

Pagina 8 - 2.3. SIM Card Installation

115.1.3. Incoming call on FXO interface 1. SmartGate detects a ringing signal and immediately interconnects it to FXS interface – the phone starts t

Pagina 9 - 2.4. Connector description

125.2. Gateway for extension line of PBX Extension line of PBX is connected to FXO interface on SmartGate. FXS interface remains unconnected. You ha

Pagina 10 - 2.8. PC Connection

135.3. Gateway for trunk line of PBX Outgoing and incoming call establishing procedures is for illustration described for analog phone connected to

Pagina 11 - 3.1. Indication LEDs

146. SMS Sending Input This universal input is intended especially for reporting alarm or error statuses of any equipment provided with the appropri

Pagina 12 - 3.2. Telephone Line Tones

Dear customer, Let us congratulate you on having purchased the SmartGate system. This new product has been developed and manufactured to provide the

Pagina 13 - 4. SIM Card PIN protection

157. COM – Serial Interface The complete serial interface RS-232C on a 9-pin connector is identical with any external modem. The transmission rate r

Pagina 14 - 4.3. Automatic PIN Entering

167.3. FAX Transmission - PC-FAX SmartGate allows fax transmissions from your PC. However, do not confuse the PC-Fax service with a standard fax ser

Pagina 15 - 5. Voice function

177.6. Combination of COM Traffic with Voice Calls As already mentioned, SMS transmission can be made even during telephone calls. The SMS program i

Pagina 16

188. SmartGate Parameter Programming Most of SmartGate’s parameters have such default values that meet most users’ demands and need not be changed.

Pagina 17

198.1.1. Basic Programming Instructions 1. Run the PCManager and select the language for displaying texts on the right-hand side. 2. Click on the CD

Pagina 18

20Caution! With regard to potential SmartGate memory data structure change, the PCManager and SmartGate are "matched" according to version

Pagina 19 - 6. SMS Sending Input

218.2. Parameter Tables All programmable parameters are listed in this section. Each parameter is accompanied with the unit used, description of Sma

Pagina 20 - 7. COM – Serial Interface

22Dial tone - cadence This tone is generated after Off-Hook in case SmartGate is ready to accept dialing. Setting options: Continuous -SmartGat

Pagina 21

23Tariff pulse when call starts/ends Signaling of call start or end by tariff pulse. Setting options: None -SmartGate doesn't send tariff

Pagina 22

24BabyCall number A number to be dialed for the automatic call function. If this item is blank, the function is disabled. Setting options: 0-20 ch

Pagina 23 - 8.1. PC based Programming

User Manual Versions Version Amendments to Earlier Versions 1.00 · The User Manual applies to SmartGate FW Version 1.00A. Upgrade The manufac

Pagina 24

25Type of transmitted dialing Set type of dialing for automatic dial-in from GSM and for dialing during outgoing call from FXS interface. Setting

Pagina 25

26Busy tone detection Set number of busy tone periods for detection of call disconnection from your PBX. The "0" setting disables busy t

Pagina 26 - 8.2. Parameter Tables

278.2.3. Routing Parameters All parameters related to the dialed number and call routing are arranged in three routing tables. Each table pertains t

Pagina 27

28are routed to GSM network. Their tariff is one impulse every 30 second and you can accelerate connection establishing by dialing of a # after the

Pagina 28

29Add The Add parameter is used for automatic call routing. A defined string (prefix) is added to the beginning of the number to be dialed. Setti

Pagina 29

30FXO routing table Calls from FXO interface are routed according to “FXO calls rote to” parameter. You can set SmartGate as DialThru gateway or as

Pagina 30

31 Password for Follow-me activation / disabling If you program SmartGate as DialThru gateway and fill in Follow-me number, function Follow-me is a

Pagina 31

32Add The Add parameter is used for automatic call routing. A defined string (prefix) is added to the beginning of the number to be dialed. Setti

Pagina 32 - FXS routing table

33GSM routing table Incoming calls from GSM contain the CLI. According to received CLI SmartGate can do following: · Reject the call; · Route the

Pagina 33

34Route to It is possible to route incoming GSM call to FSX or FXO interface, or reject it. Remaining settings are planned to use for CallBack opti

Pagina 34

Packing List SmartGate delivery contains the following items: Item Number of Pieces SmartGate 1 pc Antenna for direct connection 1 pc 1) Magnetic

Pagina 35 - FXO routing table

358.2.4. SMS Sending Input Parameters Telephone number for SMS The telephone number to which an SMS is sent upon SMS input activation. If blank,

Pagina 36

368.2.5. GSM & SIM Parameters GSM operator lock Provider blocking is set by manufacturer in SmartGate. If SmartGate is blocked to a GSM provid

Pagina 37

37Minimal credit Set minimal credit value to send warning SMS "LOW CREDIT". If credit is lower then given value, warning SMS is send afte

Pagina 38 - GSM routing table

38COM enable With this parameter you can enable/disable the serial interface function. You can disable communication in the operating mode, mainta

Pagina 39

399. Troubleshooting No LED is on after power up · Check the power supply. All LEDs are on. No call is currently in progress. · SmartGate is in t

Pagina 40

4010. List of Abbreviations · APN - Access Point Name – necessary for the GPRS service · CLIP - Calling Line Identification Presentation · CLI

Pagina 41

4111. Technical Parameters GSM: GSM module, GSM bandwidth MC45/MC55 EGSM 900 / GSM 1800 / GSM 1900 MC46/MC56 EGSM 850 / GSM 1800 / GSM 1900 Trans

Pagina 42

42SMS Sending Input: Closed loop resistance max. 1 kW Open loop resistance Min. 25 kW Input overvoltage protection max. +/- 12 V Data Interface: In

Pagina 43

CONTENTS 1. SMARTGATE PURPOSE...1 1.1. BASIC FUN

Pagina 44 - 9. Troubleshooting

1 1. SmartGate purpose 1.1. Basic Functions · The primary purpose of SmartGate is to transmit voice between GSM network and attached phone terminal

Pagina 45 - 10. List of Abbreviations

22. Installation 2.1. Proper Location · SmartGate is designed for vertical mounting on suspension holes (use the mounting pattern). This position i

Pagina 46 - 11. Technical Parameters

32.2. External Antenna Connection Screw the antenna enclosed into the SMA antenna connector. Tighten the antenna connector gently with your hand - n

Pagina 47

42.4. Connector description SMS sending input Telephone line – interface FXO RJ 11, 6/2 Telephone line – interface FXS RJ 11, 6/2 Power supply c

Comentarios a estos manuales