52.6. Power Supply Connection SmartGate is powered with 10-16V DC. Where a source other than the included power supply adapter is used, the voltage
63. SmartGate Status Indication 3.1. Indication LEDs Name Meaning Power supply · Light = SmartGate is powered. · Flashes once in 2s = HW error
73.2. Telephone Line Tones 3.2.1. Status Tones The GSM gateway sends tones to the telephone line to indicate the line status. The tone frequency is
84. SIM Card PIN protection If a SIM card is PIN-protected and the PIN is not programmed in SmartGate, GSM LED indicates the state and the PIN tone
94.3. Automatic PIN Entering You need not enter the PIN upon power up if it is stored in SmartGate – it is entered automatically. This function is u
105. Voice function Outgoing and incoming call establishing procedures is for illustration described for analog phone connected to FXS interface and
115.1.3. Incoming call on FXO interface 1. SmartGate detects a ringing signal and immediately interconnects it to FXS interface – the phone starts t
125.2. Gateway for extension line of PBX Extension line of PBX is connected to FXO interface on SmartGate. FXS interface remains unconnected. You ha
135.3. Gateway for trunk line of PBX Outgoing and incoming call establishing procedures is for illustration described for analog phone connected to
146. SMS Sending Input This universal input is intended especially for reporting alarm or error statuses of any equipment provided with the appropri
Dear customer, Let us congratulate you on having purchased the SmartGate system. This new product has been developed and manufactured to provide the
157. COM – Serial Interface The complete serial interface RS-232C on a 9-pin connector is identical with any external modem. The transmission rate r
167.3. FAX Transmission - PC-FAX SmartGate allows fax transmissions from your PC. However, do not confuse the PC-Fax service with a standard fax ser
177.6. Combination of COM Traffic with Voice Calls As already mentioned, SMS transmission can be made even during telephone calls. The SMS program i
188. SmartGate Parameter Programming Most of SmartGate’s parameters have such default values that meet most users’ demands and need not be changed.
198.1.1. Basic Programming Instructions 1. Run the PCManager and select the language for displaying texts on the right-hand side. 2. Click on the CD
20Caution! With regard to potential SmartGate memory data structure change, the PCManager and SmartGate are "matched" according to version
218.2. Parameter Tables All programmable parameters are listed in this section. Each parameter is accompanied with the unit used, description of Sma
22Dial tone - cadence This tone is generated after Off-Hook in case SmartGate is ready to accept dialing. Setting options: Continuous -SmartGat
23Tariff pulse when call starts/ends Signaling of call start or end by tariff pulse. Setting options: None -SmartGate doesn't send tariff
24BabyCall number A number to be dialed for the automatic call function. If this item is blank, the function is disabled. Setting options: 0-20 ch
User Manual Versions Version Amendments to Earlier Versions 1.00 · The User Manual applies to SmartGate FW Version 1.00A. Upgrade The manufac
25Type of transmitted dialing Set type of dialing for automatic dial-in from GSM and for dialing during outgoing call from FXS interface. Setting
26Busy tone detection Set number of busy tone periods for detection of call disconnection from your PBX. The "0" setting disables busy t
278.2.3. Routing Parameters All parameters related to the dialed number and call routing are arranged in three routing tables. Each table pertains t
28are routed to GSM network. Their tariff is one impulse every 30 second and you can accelerate connection establishing by dialing of a # after the
29Add The Add parameter is used for automatic call routing. A defined string (prefix) is added to the beginning of the number to be dialed. Setti
30FXO routing table Calls from FXO interface are routed according to “FXO calls rote to” parameter. You can set SmartGate as DialThru gateway or as
31 Password for Follow-me activation / disabling If you program SmartGate as DialThru gateway and fill in Follow-me number, function Follow-me is a
32Add The Add parameter is used for automatic call routing. A defined string (prefix) is added to the beginning of the number to be dialed. Setti
33GSM routing table Incoming calls from GSM contain the CLI. According to received CLI SmartGate can do following: · Reject the call; · Route the
34Route to It is possible to route incoming GSM call to FSX or FXO interface, or reject it. Remaining settings are planned to use for CallBack opti
Packing List SmartGate delivery contains the following items: Item Number of Pieces SmartGate 1 pc Antenna for direct connection 1 pc 1) Magnetic
358.2.4. SMS Sending Input Parameters Telephone number for SMS The telephone number to which an SMS is sent upon SMS input activation. If blank,
368.2.5. GSM & SIM Parameters GSM operator lock Provider blocking is set by manufacturer in SmartGate. If SmartGate is blocked to a GSM provid
37Minimal credit Set minimal credit value to send warning SMS "LOW CREDIT". If credit is lower then given value, warning SMS is send afte
38COM enable With this parameter you can enable/disable the serial interface function. You can disable communication in the operating mode, mainta
399. Troubleshooting No LED is on after power up · Check the power supply. All LEDs are on. No call is currently in progress. · SmartGate is in t
4010. List of Abbreviations · APN - Access Point Name – necessary for the GPRS service · CLIP - Calling Line Identification Presentation · CLI
4111. Technical Parameters GSM: GSM module, GSM bandwidth MC45/MC55 EGSM 900 / GSM 1800 / GSM 1900 MC46/MC56 EGSM 850 / GSM 1800 / GSM 1900 Trans
42SMS Sending Input: Closed loop resistance max. 1 kW Open loop resistance Min. 25 kW Input overvoltage protection max. +/- 12 V Data Interface: In
CONTENTS 1. SMARTGATE PURPOSE...1 1.1. BASIC FUN
1 1. SmartGate purpose 1.1. Basic Functions · The primary purpose of SmartGate is to transmit voice between GSM network and attached phone terminal
22. Installation 2.1. Proper Location · SmartGate is designed for vertical mounting on suspension holes (use the mounting pattern). This position i
32.2. External Antenna Connection Screw the antenna enclosed into the SMA antenna connector. Tighten the antenna connector gently with your hand - n
42.4. Connector description SMS sending input Telephone line – interface FXO RJ 11, 6/2 Telephone line – interface FXS RJ 11, 6/2 Power supply c