1112N TELEKOMUNIKACE a.s., www.2n.cz
®
Enter the command to enable/disable the use of the http interface: 0 disabled,
1 – enabled.
at^sccfg="at_port",1562
Enter the command to set the AT API port to 1562.
at^sccfg="server_restart"
Enter the command to restart the Server.2N SmartCOM
®
Caution
All the above parameters are saved into the server database but will
not become effective until the new database is loaded into the server
memory after restart.
Terminal Connection
atd<ser_no>#<port>
Enter the command to establish connection to the selected terminal and selected
port.
Note
Suppose you want to establish connection to terminal 50–0295–0562
and its RS 232 port. Enter the following command into the API:
ATD5002950562#1
+++
Enter the command to switch on the command mode for you to enter the basic
AT commands for server information and the command for connectionATH
termination.
ato
Enter the command to switch back to the data mode.
ath
Enter the command to terminate connection with the currently connected
terminal without leaving the API environment. You can go on entering commands
and establish new connections.
Terminal Communication
at^scstate<ser_no>
Vista de pagina 110