292N TELEKOMUNIKACE a.s., www.2n.cz
®
5. Conditions
2N Helios IP Automation
®
defines the following types of conditions:
ProfileState – time profile state
CallState – current call state
InputState – digital input state
LogicalAnd – logical AND of conditions
LogicalOr – logical OR of conditions
LogicalNot – condition negation
True – always true condition
False – always false condition
FlipFlopD – D-type flip-flop
FlipFlopRS – RS-type flip-flop
See below for details on the conditions and their parameters and use.
Condition.ProfileState
The block defines the condition to be met in the case of active/inactiveProfileState
time profile.
Parameters
Profile define the time profile number (1–20 depending on the intercom
model).
State – define the required profile state. This parameter is optional.
Valid values:
active – active profile (default value)
inactive – inactive profile.