2n Helios IP Automation Manual v2.7 Manual de usuario Pagina 20

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 44
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 19
202N TELEKOMUNIKACE a.s., www.2n.cz
®
Example
Activate switch 1 if the event defined on row 2 arises and the condition defined on row
3 is met:
Action.ActivateSwitch: Switch=1; Event=2; Condition=3
Action.SetOutput
The block defines the action necessary for setting of the intercom output toSetOutput
the required level.
Parameters
Event – define the event that launches the action.
Condition – define the condition to be met to execute the action. This parameter
is optional.
Output – define the output to be set.
Valid values:
relay1 – relay 1 on basic unit
relay2 – relay 2 on basic unit
output1 – output 1 on basic unit
output2 – output 2 on basic unit
cr_relay1 – relay 1 on card reader
cr_relay2 – relay 2 on card reader
cr_output – output 1 on card reader
redled - red LED indicator
led1 – LED 1 indicator
led2 – LED 2 indicator
led3 – LED 3 indicator.
There may be different lists of valid values for different 2N Helios IP
®
models; refer to the Available Digital Inputs and Outputs subsection.
Level – define the required output level. This parameter is optional.
Valid values:
0 – output deactivation
1 – output activation (default value).
Example
Activate Output1 if the event defined on row 2 arises:
Action.SetOutput: Output=output1; Event=2
Vista de pagina 19
1 2 ... 15 16 17 18 19 20 21 22 23 24 25 ... 43 44

Comentarios a estos manuales