Block diagram
The rising edge on the tamper input (1: Event.InputChanged) initiates calling to the
defined telephone number (5: Action.BeginCall) in case the defined condition is met.
The condition (4: Condition.FlipFlopRS) is validated by the intercom restart or entering
the selected code (2: Condition.CodeEntered) from the numerical keypad. If another
code is entered (3: Condition.CodeEntered), the condition will be invalid.
Intercom settings
1: Event.InputChanged: Input=tamper; Edge=rising
2: Event.CodeEntered: Code=164575
3: Event.CodeEntered: Code=111
4: Condition.FlipFlopRS: SetEvent=3; ResetEvent=2; ResetValue=1
5: Action.BeginCall: Number=1111; Event=1; Condition=4
Door Opening by RFID Card
Specification
Activate the door contact switch by entering the proper RFID card.
Block diagram
Entering an RFID card with the defined ID (1: Event.CardEntered) activates switch 1
(2: Action.ActivateSwitch).