82N TELEKOMUNIKACE a.s., www.2n.cz
®
Every event defines the and variables.TimeStamp Count
TimeStamp contains encoded date and time of the last event generation in the Unix
Time format (second count from 00:00:00 1.1.1970).
Count contains the count of event generations after the device start or last block
configuration change. The variable increases by 1 after each event generation.
Refer to the following subsections for more variables with specific functions.
Tip
The Upper/Lower case is not be respected in the variable names.
Caution
You cannot use the variables in the block relation defining parameters, i.e.
Event, Condition, etc.