302N TELEKOMUNIKACE a.s., www.2n.cz
®
Condition.CallState
The block defines the condition to be met in the case of a defined state ofCallState
the currently made call.
Parameters
State – define the call state.
Valid values:
idle – call is not being made
connecting call setup in progress
ringing – ringing in progress
connected – call connected.
Direction – define the call direction.
Valid values:
incoming – incoming calls
outgoing – outgoing calls
any – both directions.
The parameter is optional, the default value is .any
Example
The condition is met for an inactive call:
Condition.CallState: State=Idle
Condition.InputState
The block defines the condition to be met in case the defined logic levelInputState
gets connected to the defined digital input.
Parameters
Input – define the digital input.
Valid values:
tamper – tamper switch
input1 – digital input 1
input2 – digital input 2
cr_input1 – digital input 1 on card reader
cr_input2 – digital input 2 on card reader.
There may be different lists of valid values for different 2N Helios IP
®
models; refer to the Available Digital Inputs and Outputs subsection.
Level – define the required digital input level. The parameter is optional.
Valid values:
0 – logic 0
1 – logic 1 (default value).