2n Helios IP Configuration Manual v2.7 Manual de usuario Pagina 35

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 115
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 34
352N TELEKOMUNIKACE a.s., www.2n.cz
®
List of Parameters
Switch enabled enable/disable the switch globally. When disabled, the switch
cannot be activated by any of the available codes (including user switch codes),
by a call or quick dial button.
Switch mode set the monostable/bistable mode for the switch. The switch is
switched off after a timeout in the monostable mode, and switched on with the
first activation and off with the next activation in the bistable mode.
Switch-on duration set the switch-on time for a monostable switch. This
value is not applied in the bistable mode.
Time profile assign the switch a time profile to enable switch-on. If the time
profile is inactive, the switch cannot be activated by a code, call or quick dial
button.
Controlled output assign an electric output to the switch. Choose one of the
available intercom outputs: relay, power output, extender output. If you select
, the switch will not control any electric output but can control externalNone
equipment via HTTP commands.
Output type if you use the Security Relay module, set the 2N Helios IP
®
output type to . In the mode, the output works in the inverseSecurity Security
mode, i.e. remains closed and controls the Security Relay module 2N Helios IP
®
using a specific pulse sequence.
Note
Switch time profiles are available with the Gold or Enhanced Integration
licence only.